{"id":100,"date":"2010-12-31T00:00:18","date_gmt":"2010-12-30T22:00:18","guid":{"rendered":"http:\/\/www.data-protector.org\/wordpress\/?p=100"},"modified":"2015-12-10T19:54:28","modified_gmt":"2015-12-10T18:54:28","slug":"disable-device-polling","status":"publish","type":"post","link":"https:\/\/www.data-protector.org\/wordpress\/de\/2010\/12\/disable-device-polling\/","title":{"rendered":"Disable Device Polling"},"content":{"rendered":"<p>In einem anderen Artikel <a href=\"https:\/\/www.data-protector.org\/wordpress\/2010\/12\/was-ist-eigentlich-device-polling\/\">&#8222;What is device polling&#8220;<\/a> \u00a0hatte ich beschrieben was Device Polling ist und welche Auswirkungen das auf ein backup haben kann. Hier versuche ich nun aufzuzeigen wie man Device Polling verhindert.<br \/>\nBleibt zu erw\u00e4hnen das nachfolgende Hinweise f\u00fcr anst\u00e4ndige Hardware &#8211; HP &#8211; gelten. Wenn man gezwungen ist Data Protector auf F***** oder I** oder D*** Servern zu installieren, so ist die entsprechende Doku des Herstellers zu verwenden.<br \/>\nGenerell gilt: Device Polling muss auf allen Servern deaktiviert werden welche Bandlaufwerke im SAN &#8222;sehen&#8220; k\u00f6nnen. Server die nicht Bandlaufwerke sehen m\u00fcssen sind in eine separate Zone auf den SAN Switchen zu schieben. Nach M\u00f6glichkeit sollte immer 1:1 Zoning genutzt werden. Auf den MSL 6000 kann es helfen eine leere indexed map zu haben (somit werden neue Server nicht zugeordnet) und eine zus\u00e4tzliche Map im NSR zu generieren.<\/p>\n<ul>\n<li>Deaktivieren von Netzwerkscannern: NMAP oder 3com Network Director sind daf\u00fcr bekannt Netzwerktraffic auf dem NSR zu senden, der sporadische Reboots der NSR&#8217;s verursachen kann. Scans sollte nur in der backupfreien Zeit stattfinden.<\/li>\n<li>Unter Windows werden sogenannte TUR (Test Unit Ready) Komanndos in periodischen Abst\u00e4nden an den SCSI Bus gesendet (Windows 2000 &#8211; alle 3 Sekunden, Windows 2003 &#8211; jede Sekunde). Dieses Verhalten tritt sofort auf wenn ein neuer Server installiert wird und dieser Server SAN Zugriff hat. Windows 2008 ist nur dann betroffen, wenn dort der Wechselmediendienst (RSM) als zus\u00e4tzliches Feature installiert wird. Prinzipiell ist der Wechselmediendienst zu deaktivieren und zus\u00e4tzlich dem Bandlaufwerkstreiber TUR zu entw\u00f6hnen (siehe auch Folgepunkt). Microsoft hat hierf\u00fcr einen KB Artikel 842411:\u00a0<a href=\"http:\/\/support.microsoft.com\/default.aspx?scid=kb;en-us;842411\">http:\/\/support.microsoft.com\/default.aspx?scid=kb;en-us;842411<\/a>. Zus\u00e4tzlicher Hinweis: wenn man einen Server abschaltet und f\u00fcr neue Zwecke neu installieren m\u00f6chte, so sollte man auch das Zoning beim &#8222;R\u00fcckbau&#8220; \u00fcberpr\u00fcfen, da beim Neuinstallieren des Servers mit Windows das Problem sofort wieder auftreten kann.<\/li>\n<li>F\u00fcr HP LTO muss die aktuellste Version der Treiber eingesetzt werden, da eine \u00e4ltere Version (1.0.3.0) im Installationsfile das Polling immer aktiviert. Prinzipiell muss der folgende Registry Key f\u00fcr jedes Laufwerk\u00a0(Laufwerkstyp &#8211; hplto, hpdlt, &#8230;) eingetragen werden und danach der Server neu gestartet werden, unter Umst\u00e4nden muss auch der NSR neu gestartet werden. Die Schritte sind auch f\u00fcr die Robotic notwendig (libxprmc, hpmc oder hpuln32).<\/li>\n<\/ul>\n<ul>\n<li>HKLM\\SYSTEM\\CurrentControlSet\\Services\\hplto<\/li>\n<li>neuen DWORD anlegen, Name AutoRun, Wert=0<\/li>\n<\/ul>\n<li>Insight Management Agents senden in periodischen Abst\u00e4nden Statusabfragen an die Laufwerke um Fehler erkennen zu k\u00f6nnen. In der Systemsteuerung ist das Programm HP Management Agents zu \u00f6ffnen und im Tab Storage &#8222;Disable Fibre Agent Tape Support&#8220; zu aktivieren.<\/li>\n<p>Auch auf UNIX kann es zum Pollen der Devices kommen:<\/p>\n<ul>\n<li>HP-UX 11.23 (v2) reicht es aus den Kernel Parameter st_san_safe zu setzen &#8211;&gt; <code>kctune st_san_safe=1<\/code><\/li>\n<li>F\u00fcr HP-UX 11.31 (v3) gibt es einen neuen Parameter, hierf\u00fcr ist jedoch Patch PHKL_36312 erforderlich:<\/li>\n<\/ul>\n<ul>\n<li>Setzen des Wertes: <code>scsimgr set_attr -d estape -a norewind_close_disabled=1<\/code><\/li>\n<li>Speichern des Wertes: <code>scsimgr save_attr -d estape -a norewind_close_disabled=1<\/code><\/li>\n<li>\u00dcberpr\u00fcfen des Wertes: <code>scsimgr - estape get_attr<\/code><\/li>\n<\/ul>\n<p>Und wie kann man das dann alles noch kontrollieren? Auf einem NSR kann man die Traces leeren und bei nichtlaufendem Backup pr\u00fcfen wieviele Eintr\u00e4ge geschrieben werden, device polling\u00a0w\u00fcrde hier sehr viele Eintr\u00e4ge in Sekunden anzeigen.<\/p>\n<p>Anmerkung generell: Polling wird zwar immer noch passieren, aber mit den ergriffenen Ma\u00dfnahmen nicht mehr in der Masse. Ein unter HP-UX abgesetztes ioscan, unter Windows ausgef\u00fchrtes &#8222;Nach ge\u00e4nderter Hardware suchen&#8220; oder ein ausgef\u00fchrtes LTT werden trotzdem ein wenig device polling durchf\u00fchren, dieses Verhalten ist aber in einem akzeptablen Ma\u00dfe.<\/p>\n<p>Und weil ich grade LTT erw\u00e4hnt habe. Dieses Tool kann mittlerweile auch genau dokumentieren welcher HBA TUR verursacht; mit einer sauber gepflegten SAN Doku sollte man dann sehr schnell den verursachenden Server finden k\u00f6nnen. Das LTT Tool gibt es \u00fcbrigens hier: (Wusstet hier dass es das Tool f\u00fcr Netware gibt? &#8211; Ich bin Master CNE&#8230;)<a href=\"http:\/\/h20000.www2.hp.com\/bizsupport\/TechSupport\/DriverDownload.jsp?lang=de&amp;cc=de&amp;prodNameId=406731&amp;taskId=135&amp;prodTypeId=12169&amp;prodSeriesId=406729&amp;lang=de&amp;cc=de\">http:\/\/h20000.www2.hp.com\/bizsupport\/TechSupport\/DriverDownload.jsp?lang=de&amp;cc=de&amp;prodNameId=406731&amp;taskId=135&amp;prodTypeId=12169&amp;prodSeriesId=406729&amp;lang=de&amp;cc=de<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>In einem anderen Artikel &#8222;What is device polling&#8220; \u00a0hatte ich beschrieben was Device Polling ist und welche Auswirkungen das auf ein backup haben kann. Hier versuche ich nun aufzuzeigen wie man Device Polling verhindert. Bleibt zu erw\u00e4hnen das nachfolgende Hinweise f\u00fcr anst\u00e4ndige Hardware &#8211; HP &#8211; gelten. Wenn man gezwungen ist Data Protector auf F***** [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_mi_skip_tracking":false,"spay_email":""},"categories":[11],"tags":[45,46,55],"translation":{"provider":"WPGlobus","version":"2.8.8","language":"de","enabled_languages":["en","de"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"de":{"title":false,"content":true,"excerpt":false}}},"jetpack_featured_media_url":"","jetpack_shortlink":"https:\/\/wp.me\/p28cjj-1C","jetpack_sharing_enabled":true,"jetpack-related-posts":[{"id":87,"url":"https:\/\/www.data-protector.org\/wordpress\/de\/2010\/12\/was-ist-eigentlich-device-polling\/","url_meta":{"origin":100,"position":0},"title":"What is device polling","date":"31. Dezember 2010","format":false,"excerpt":"{:de}Bestimmt jeder Data Protector Kunde mit einer Fibre Channel Tape Library hat dieses Problem schon mal wissentlich oder unwissentlich erlebt: ein SCSI Reset w\u00e4hrend einer Sicherung... und das ganze Band ist zerst\u00f6rt. Was war passiert? Das Bandlaufwerk wurde mit\u00a0SCSI Kommandos \u00fcbersch\u00fcttet - das nennt man auch Device Polling. Polling ist\u2026","rel":"","context":"In &quot;Common&quot;","img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":126,"url":"https:\/\/www.data-protector.org\/wordpress\/de\/2010\/08\/enhanced-automated-disaster-recovery\/","url_meta":{"origin":100,"position":1},"title":"Enhanced Automated Disaster Recovery","date":"6. August 2010","format":false,"excerpt":"{:en}No translation for this article available.{:} {:de} Immer wieder mal ben\u00f6tigt man es wenn ein Server komplett den Bach runter geht... \u00a0In der Regel sollte man vor einem Disaster wissen wie man seine Server wieder herstellt. In den Unterlagen von HP ist zwar sehr sch\u00f6n und ausf\u00fchrlich beschrieben welche einzelnen\u2026","rel":"","context":"In &quot;HowTo&quot;","img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":2948,"url":"https:\/\/www.data-protector.org\/wordpress\/de\/2016\/03\/set-data-protector-smart-cache-power-live-migrate\/","url_meta":{"origin":100,"position":2},"title":"How to set up Data Protector to use Smart Cache for Power On and Live Migrate","date":"8. M\u00e4rz 2016","format":false,"excerpt":"{:en} With HPE Data Protector you have advance VM recovery functionality when backing up using either a 3Par or Smart Cache device. To give you some background on why this is the supported method is due to the flow\/process that Data Protector uses when doing this type of recovery. Once\u2026","rel":"","context":"In &quot;HowTo&quot;","img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":2042,"url":"https:\/\/www.data-protector.org\/wordpress\/de\/2014\/07\/physical-tape-vs-virtual-tape\/","url_meta":{"origin":100,"position":3},"title":"Physical Tape vs. Virtual Tape","date":"13. Juli 2014","format":false,"excerpt":"{:en}In a modern Backup & Recovery infrastructure backup-to-disk solutions are used very often. But many customers need to look at capex and opex. With the implementation of modern deduplication technologies these expenses can be decreased very easily. However, to save money, you have to follow some rules, otherwise the backup-to-disk\u2026","rel":"","context":"In &quot;Common&quot;","img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":4128,"url":"https:\/\/www.data-protector.org\/wordpress\/de\/2018\/05\/data-protector-10-patch-bundle-a-10-04-build-182\/","url_meta":{"origin":100,"position":4},"title":"Data Protector 10 \u2013 Patch Bundle A.10.04 (Build 182)","date":"23. Mai 2018","format":false,"excerpt":"{:en}The Patch Bundle A.10.04 (Build 182) for Data Protector 10 has been released on May 22, 2018. Data Protector A.10.03 was released as a full install therefore the cumulative patch 10.04 can only be installed on top of A.10.03. A direct upgrade from A.10.00, A.10.01 or A.10.02 is not possible!\u2026","rel":"","context":"In &quot;DP A.10.00&quot;","img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":1365,"url":"https:\/\/www.data-protector.org\/wordpress\/de\/2013\/05\/ipc-invalid-packet-size\/","url_meta":{"origin":100,"position":5},"title":"IPC Invalid Packet Size","date":"8. Mai 2013","format":false,"excerpt":"{:en}After the upgrade to DP 7.01 in some environments the rarley error IPC Invalid Packet Size has been seen while accessing a changer or tape device. The problem might be related to a slow name resolutuion on the media agent. The INET may run into a timeout before sending data\u2026","rel":"","context":"In &quot;HowTo&quot;","img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]}],"_links":{"self":[{"href":"https:\/\/www.data-protector.org\/wordpress\/de\/wp-json\/wp\/v2\/posts\/100"}],"collection":[{"href":"https:\/\/www.data-protector.org\/wordpress\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.data-protector.org\/wordpress\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.data-protector.org\/wordpress\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.data-protector.org\/wordpress\/de\/wp-json\/wp\/v2\/comments?post=100"}],"version-history":[{"count":14,"href":"https:\/\/www.data-protector.org\/wordpress\/de\/wp-json\/wp\/v2\/posts\/100\/revisions"}],"predecessor-version":[{"id":2854,"href":"https:\/\/www.data-protector.org\/wordpress\/de\/wp-json\/wp\/v2\/posts\/100\/revisions\/2854"}],"wp:attachment":[{"href":"https:\/\/www.data-protector.org\/wordpress\/de\/wp-json\/wp\/v2\/media?parent=100"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.data-protector.org\/wordpress\/de\/wp-json\/wp\/v2\/categories?post=100"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.data-protector.org\/wordpress\/de\/wp-json\/wp\/v2\/tags?post=100"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}