{"id":2372,"date":"2015-08-27T18:48:04","date_gmt":"2015-08-27T17:48:04","guid":{"rendered":"http:\/\/www.data-protector.org\/wordpress\/?p=2372"},"modified":"2015-12-09T17:15:09","modified_gmt":"2015-12-09T16:15:09","slug":"tested-poweronrun-live-migrate-3par-snapshots-smartcache","status":"publish","type":"post","link":"https:\/\/www.data-protector.org\/wordpress\/2015\/08\/tested-poweronrun-live-migrate-3par-snapshots-smartcache\/","title":{"rendered":"TESTED: PowerOn&#038;Run and Live Migrate from 3PAR Snapshots or SmartCache"},"content":{"rendered":"<p>With Data Protector 9.04 the new features PowerOn &#038; Run and Live Migrate from 3PAR snapshots or SmartCache were introduced. This feature allows to power on and test virtual machines (VMware), backed up using the VE integration. Recently I had the opportunity to implement this feature in a proof of concept and to present the solution to the customer. I have also been able to talk with some partners and customers meanwhile and bottom line is: a successful implementation! Some discussions around these features lead to the question whether Veeam is still required as supplementary backup solution, as Data Protector provides one more time an another attractive recovery option for virtual machines in Enterprise environments.<\/p>\n<p>\nIn the mentioned PoC I had performed the backup of multiple virtual machines into the SmartCache. In addition I backed up some machines using Zero Downtime Backup and implemented it into the customers backup and recovery strategy. PowerOn and Migrate worked perfectly when I used 3PAR snapshots and the SmartCache and I encourage all customers to test these new Data Protector features. If no 3PAR in place, no problem, you can perform the test with the SmartCache as I did in addition.<\/p>\n<p>Speaking perfectly, two problems raised up. In one case, an error message when turning on the virtual machine was displayed: &#8220;A question needs to be answered before power on can be completed&#8221; and as a result &#8220;Error powering on&#8221;. In the second case, an error message came: &#8220;Share presentation failed&#8221; and as a result &#8220;Power On Virtual Machine failed&#8221;. In both cases, however, Data Protector has shown only a consequence of failure of another cause. Before anyone comes across the same error, follow the explanation of the cause.<\/p>\n<p><b>&#8220;A question needs to be answered before power on can be completed&#8221;<\/b><br \/> <br \/>\nUsing Virtual Center, the unanswered question was displayed with the comment &#8220;Diese virtuelle Maschine wurde m\u00f6glicherweise verschoben oder kopiert&#8230;&#8221; (German message). In debug files following was seen:<\/p>\n<blockquote style=\"font: 12px Courier; background-color: #ffffff; border: 1px solid #ccc; border-radius: 6px; box-shadow: 1px 1px 1px #ccc;\">\n<pre style=\"border: 0px\">\r\n[ 99] 2015-08-19 14:23:46.463 (\"\/integ\/vep\/vepa\/Plugins\/Vmware\/VmwareHelpers\/ConfigUtil.cpp $Rev: 49146 $ $Date:: \":293)\r\n[ 99] ===>> (6) ConfigUtil::answerQuestion {\r\n[ 99] \r\n[ 20] [ConfigUtil::answerQuestion] waiting for different question\r\n_vmx1\r\nDiese virtuelle Maschine wurde m\u00f6glicherweise verschoben oder kopiert. Um bestimmte Verwaltungs- und Netzwerkfunktionen konfigurieren zu k\u00f6nnen, muss VMware ESX wissen, ob diese virtuelle Maschine verschoben oder kopiert wurde. Wenn Sie es nicht wissen, antworten Sie mit \"Ich habe sie kopiert\". \r\n[ 20] [ConfigUtil::answerQuestion] Throwing exception: class std::runtime_error\r\n<\/pre>\n<\/blockquote>\n<p>Hold On! German error message in Data Protector? The Virtual Center Server definitely was installed with English Locale, however, the service and user was not set to English Locale. So wondering why I translated this topic for you? The error might appear to you too, especially when not located in native English speaking countries. With the link (Thanks to Sebastian): <a href=\"http:\/\/kb.vmware.com\/selfservice\/microsites\/search.do?language=en_US&#038;cmd=displayKC&#038;externalId=2121646\" target=\"_newvm\">http:\/\/kb.vmware.com\/selfservice\/microsites\/search.do?language=en_US&#038;cmd=displayKC&#038;externalId=2121646<\/a> the cause was fixed very soon and PowerOn and Migrate worked as expected.\n<\/p>\n<p><b>&#8220;Share presentation failed&#8221;<\/b> <\/p>\n<blockquote style=\"font: 12px Courier; background-color: #ffffff; border: 1px solid #ccc; border-radius: 6px; box-shadow: 1px 1px 1px #ccc;\">\n<pre style=\"border: 0px\">\r\n[Normal] From: &#x52;&#x53;&#x4d;&#x40;&#x68;&#x70;&#x63;&#x73;&#x2e;&#x63;&#x75;&#x73;&#x74;&#x6f;&#109;&#101;&#114;&#46;&#108;&#111;cal \"\"  Time: 8\/10\/2015 9:54:59 AM\r\n\tRestore session 2015\/08\/10-10 started.\r\n\r\n[Normal] From: &#x52;&#x4d;&#x41;&#x40;&#x68;&#x70;&#x63;&#x73;&#x2e;&#x63;&#x75;&#115;&#116;&#111;&#109;er.local \"SmartCache_gw1 [GW 18252:0:17740599057275740933]\"  Time: 8\/10\/2015 9:55:38 AM\r\n\tSTARTING Media Agent \"SmartCache_gw1 [GW 18252:0:17740599057275740933]\"\r\n\r\n[Normal] From: &#x52;&#77;A&#x40;&#104;p&#x63;&#x73;.c&#x75;&#115;t&#x6f;&#x6d;er&#x2e;&#108;o&#x63;&#x61;l \"SmartCache_gw1 [GW 18252:0:17740599057275740933]\"  Time: 8\/10\/2015 9:55:39 AM\r\n\tLoading medium from slot \\\\hpcs.customer.local\\D:\\Cache\\358d640a_55d57510_0908_13a1 to device SmartCache_gw1 [GW 18252:0:17740599057275740933]\r\n\r\n[Major] From: R&#x4d;&#x41;&#64;&#104;&#x70;c&#115;&#x2e;&#x63;u&#x73;&#x74;o&#109;&#x65;r&#46;&#x6c;&#x6f;c&#x61;&#x6c; \"SmartCache_gw1 [GW 18252:0:17740599057275740933]\"  Time: 8\/10\/2015 9:55:45 AM\r\n\tShare presentation failed.\r\n\r\n[Major] From: OB&#50;&#x42;&#x41;&#x52;&#x5f;VE&#65;&#103;&#x65;&#x6e;&#x74;&#64;hp&#99;&#x73;&#x2e;&#x63;ust&#111;&#x6d;&#x65;&#x72;.lo&#99;&#x61;&#x6c; \"\/DATACENTER\"  Time: 8\/10\/2015 9:55:45 AM\r\n\tReceived ABORT request from RSM (ERR: Error starting backup\/restore (BMA cannot be started or similar).)\r\n\r\n[Major] From: VE&#80;&#x41;&#x4c;IB&#95;&#x56;&#x4d;&#x57;AR&#69;&#x40;&#x68;pc&#115;&#x2e;&#x63;&#x75;st&#111;&#x6d;&#x65;r.&#108;&#x6f;&#x63;&#x61;l \"\/DATACENTER\"  Time: 8\/10\/2015 9:55:45 AM\r\n\tPreparation of replica vm 'virtualmachine' for restore failed ...\r\n\r\n[Critical] From: VEPALIB&#95;&#86;&#77;&#87;&#x41;&#x52;&#x45;&#x40;&#x68;&#x70;&#x63;&#x73;&#x2e;custome&#114;&#46;&#108;&#111;&#x63;&#x61;&#x6c; \"\/DATACENTER\"  Time: 8\/10\/2015 9:55:45 AM\r\n\tPower On Virtual Machine failed.\r\n<\/pre>\n<\/blockquote>\n<p>After some debugging I found that port 111 was in use (<code> nestat -ano<\/code>). A look at the process list for the given PID indicated the responsible process &#8211; ONC \/ RPC Portmapper. The process (from QLogic&#8217;s OneCommand) occupied the port 111 and thus prevented a start of the NFS service. Solution: Disable the service ONC \/ RPC portmapper, start NFS service, and immediately the presentation to the ESX server is working.<\/p>\n<p>By the way: to purge the powered on machines the command <code>omnidbutil<\/code>was enhanced. With command <code>omnidbutil -purge_expired_poweron_vms -daily<\/code> you can cleanup the environment.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>With Data Protector 9.04 the new features PowerOn &#038; Run and Live Migrate from 3PAR snapshots or SmartCache were introduced. This feature allows to power on and test virtual machines (VMware), backed up using the VE integration. Recently I had the opportunity to implement this feature in a proof of concept and to present the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_mi_skip_tracking":false,"spay_email":""},"categories":[11],"tags":[],"translation":{"provider":"WPGlobus","version":"2.8.8","language":"en","enabled_languages":["en","de"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"de":{"title":false,"content":true,"excerpt":false}}},"jetpack_featured_media_url":"","jetpack_shortlink":"https:\/\/wp.me\/p28cjj-Cg","jetpack_sharing_enabled":true,"jetpack-related-posts":[{"id":2363,"url":"https:\/\/www.data-protector.org\/wordpress\/2015\/08\/data-protector-patch-bundle-9-04-features\/","url_meta":{"origin":2372,"position":0},"title":"Data Protector 9 &#8211; Patch Bundle 9.04 (Build 104)","date":"5. August 2015","format":false,"excerpt":"{:en}On 2015\/08\/06 HP released patch bundle 9.04 for Linux, HP-UX and Windows, it includes 494 changes for Windows and 439 changes for Linux. With the new bundle some new and important features were introduced (complete list - see patch description): Power-On a VMware virtual machine from 3PAR snapshot or from\u2026","rel":"","context":"In &quot;DP A.09.00&quot;","img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":2381,"url":"https:\/\/www.data-protector.org\/wordpress\/2015\/09\/step-step-poweron-migrate-from-3par-snapshots\/","url_meta":{"origin":2372,"position":1},"title":"Step by Step: Power On and Live Migrate from 3PAR Snapshots","date":"9. September 2015","format":false,"excerpt":"{:de}Nachdem ich den Artikel https:\/\/www.data-protector.org\/wordpress\/2015\/08\/tested-poweronrun-live-migrate-3par-snapshots-smartcache\/ ver\u00f6ffentlicht hatte, haben einige Leser den Wunsch ge\u00e4u\u00dfert eine etwas ausf\u00fchrlichere Anleitung f\u00fcr die im Data Protector 9.04 eingef\u00fchrte Funktion Power On und Live Migrate von 3PAR Snapshots oder Smartcache zu erhalten. Daf\u00fcr und f\u00fcr die grunds\u00e4tzlichen Konzepte zu Zero Downtime Backup stehen die Guides\u2026","rel":"","context":"In &quot;HowTo&quot;","img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":3097,"url":"https:\/\/www.data-protector.org\/wordpress\/2016\/06\/hpe-data-protector-7-0x-8-0x-eol\/","url_meta":{"origin":2372,"position":2},"title":"HPE Data Protector 7.0X and 8.0X &#8211; EOL","date":"3. June 2016","format":false,"excerpt":"{:en} The time has come, this month the support for Data Protector 7.0x and 8.0x Data Protector will end. Support for version 8.1x will end 30\/06\/2017. Of course, all customers with an active maintenance contract can upgrade to the current Data Protector version 9.0x. Data Protector 9.0x includes enhancements like:\u2026","rel":"","context":"In &quot;Data Protector Links&quot;","img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.data-protector.org\/wordpress\/wp-content\/uploads\/2016\/06\/eol.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":1588,"url":"https:\/\/www.data-protector.org\/wordpress\/2013\/09\/backup-performance\/","url_meta":{"origin":2372,"position":3},"title":"Backup performance","date":"23. September 2013","format":false,"excerpt":"{:en}If it matters, you had better trust on HP Data Protector to get fast backups and to achieve your backup windows. During the implementation of a StoreOnce appliance with a partner of HP, the following performance values were achieved (see pictures below). The environment: a backup of 5 virtual machines\u2026","rel":"","context":"In &quot;Common&quot;","img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":1623,"url":"https:\/\/www.data-protector.org\/wordpress\/2013\/10\/dp-8-ve-integration-requested-operation-timed\/","url_meta":{"origin":2372,"position":4},"title":"DP 8.0 and VE integration &#8211; requested operation timed out","date":"14. October 2013","format":false,"excerpt":"{:en}With Data Protector 8.0 and when a backup for virtual machines, using the \"Virtual Environment Integration\", is performed, a message might be displayed \"Requested operation timed out\". The message has been seen, when long-running snapshots are created by the Virtual Center server. The timeout occurs after 60 seconds. The root\u2026","rel":"","context":"In &quot;Common&quot;","img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":1328,"url":"https:\/\/www.data-protector.org\/wordpress\/2013\/04\/vmware-backup-nbd-san\/","url_meta":{"origin":2372,"position":5},"title":"VMware backup done over NBD instead of SAN","date":"11. April 2013","format":false,"excerpt":"{:en}Problem: The backup of some virtual machines is done using transport mode NBD instead of SAN, even if it is configured for the virtual machine or a vApp container. There might be other virtual machines on the same SAN disk, which are able to do the backup over SAN. The\u2026","rel":"","context":"In &quot;HowTo&quot;","img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]}],"_links":{"self":[{"href":"https:\/\/www.data-protector.org\/wordpress\/wp-json\/wp\/v2\/posts\/2372"}],"collection":[{"href":"https:\/\/www.data-protector.org\/wordpress\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.data-protector.org\/wordpress\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.data-protector.org\/wordpress\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.data-protector.org\/wordpress\/wp-json\/wp\/v2\/comments?post=2372"}],"version-history":[{"count":9,"href":"https:\/\/www.data-protector.org\/wordpress\/wp-json\/wp\/v2\/posts\/2372\/revisions"}],"predecessor-version":[{"id":2494,"href":"https:\/\/www.data-protector.org\/wordpress\/wp-json\/wp\/v2\/posts\/2372\/revisions\/2494"}],"wp:attachment":[{"href":"https:\/\/www.data-protector.org\/wordpress\/wp-json\/wp\/v2\/media?parent=2372"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.data-protector.org\/wordpress\/wp-json\/wp\/v2\/categories?post=2372"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.data-protector.org\/wordpress\/wp-json\/wp\/v2\/tags?post=2372"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}